Downloads
Abstract
Single-stage topology and the maximum power point tracking (MPPT) algorithm have advantages such as simple configuration and high efficiency in grid-connected photovoltaic (PV) systems. In conventional systems, current and voltage sensors of PV system are normally used for MPPT. This paper presents a modified control algorithm for the single-stage three-phase grid-connected PV system without PV current sensor with a variable step MPP-tracker. This algorithm is not derived from complex state equations and is not dependent on any circuit parameters. It simply calculates the output power of the inverter to replace the input power of the PV systems in the MPPT algorithm. The modified algorithm is simulated by using Matlab/Simulink software and implemented in the experimental prototype. With the single-stage configuration and PV current sensorless method, the prototype is suitable for lowcost high efficient implementation in the practice.
Issue: Vol 16 No 4 (2013)
Page No.: 19-32
Published: Dec 31, 2013
Section: Engineering and Technology - Research article
DOI: https://doi.org/10.32508/stdj.v16i4.1581
Download PDF = 893 times
Total = 893 times