Downloads
Abstract
In this work, we developed a Fortran code (CalcTotEff) to calculate the intrinsic and total efficiencies of a 3 in x 3 in NaI(Tl) crystal by using the hybrid Monte Carlo method. To confirm the reliability of the results of the total efficiency calculated, an experimental arrangement was set up. The results showed the compatibility between the calculated and experimental data. We also used the hybrid Monte Carlo method to evaluate the dependence of the intrinsic efficiency on d/R ratio (d is the distance from the surface detector to point source and R is the radius of NaI(Tl) crystal).
Issue: Vol 16 No 4 (2013)
Page No.: 26-34
Published: Dec 31, 2013
Section: Natural Sciences - Research article
DOI: https://doi.org/10.32508/stdj.v16i4.1593
Download PDF = 617 times
Total = 617 times
Most read articles by the same author(s)
- Chuong Dinh Huynh, Dan Tieu Luu, Nguyen Hoang Vo, Thanh Thien Tran, Tao Nhat Chau, An analytical calculation model of the full energy peak efficiency for cylindrical detectors used in assays of radioactive waste drums , Science and Technology Development Journal: Vol 19 No 2 (2016)
- Ngan Thao Nguyen, Thanh Thien Tran, Tao Van Chau, Vuong Quang Le, Binh Thi Nguyen, Tam Duc Hoang, Calculation of Compton cross section of aluminum, iron, copper, C45 and CT3 steels in the range of 250 keV– 2600 keV , Science and Technology Development Journal: Vol 18 No 1 (2015)
- Lang Hoang Trinh, Tao Van Chau, Chien Hoang Le, Hong Thi Yen Huynh, Tram Ngoc Huynh, Positron annihilation rate in single atom with slater type orbital approximation , Science and Technology Development Journal: Vol 16 No 4 (2013)
- Thanh Thien Tran, Tao Van Chau, Tam Duc Hoang, Yen Thi Hong Vo, STUDY ON THE EFFECT OF NATURAL BACKGROUND FOR GAMMA SPECTROMETER SYSTEM , Science and Technology Development Journal: Vol 14 No 4 (2011)
- Hao Cong Le, Nhon Van Mai, Tao Van Chau, DETERMINATION OF FOILS THICKNESS BY ALPHA SPECTROSCOPY , Science and Technology Development Journal: Vol 13 No 1 (2010)