The analyses on Joule-Brayton cycle, which could be used for a high efficiency power generation system, using the temperature and the pressure of compressor have been carried out. As a result, when the ratio of maximum temperature to the minimum temperature in the cycle increased, the thermal efficiency increased. By analyzing the efficiency and the output power, it is understood that the ratio of compressor outlet pressure to the compressor inlet pressure, as well as the pressure ratio across the compressor for maximum thermal efficiency and maximum output power are different. The maximum thermal efficiency could be an important technical parameter; however, the maximum output power is significant in the cost and the size of system. For that reason, depending on the required system for maximum efficiency or for maximum power, the ratio of temperature and pressure are designed
Issue: Vol 12 No 4 (2009)
Page No.: 39-46
Published: Feb 28, 2009
Section: Article
DOI: https://doi.org/10.32508/stdj.v12i4.2230
Download PDF = 667 times
Total = 667 times